Inviting quotations from various agencies to replace/refill the existing fire extinguishers installed at 14 FRIENDS Janasevanakendram with the following specifications;

Last date of submission - 30th September 2014

Mono Ammonium Phosphate 90 (02 Kg) - Required Nos - 24
  • The current and valid BIS certification IS 15683:2006 needs to be submitted along with offer.
  • Dry Chemical powder used as extinguishing agent should be Mono Ammonium Phosphate with more than 90% concentration conforming to IS 14609:1999.
  • MSDS of the powder needs to be submitted along with the offer.
  • The Product should be EN Approved and CE marked.
  • The Manufacturer has to submit 5 years warranty on the extinguishers
  • Vessel used in the manufacturing should be constructed using Deep Drawn Technology to keep seamless area not less than 70% of the cylinder.
  • Each vessel needs to be checked for tensile strength upto 35 kgf/cm2 and Manufacturer has to submit Hydrostatic pressure testing certificate for the same.
  • The extinguishers should be pressurized using high grade Dry Nitrogen as per IS 1747 standard. OEM declaration should be submitted.
  • In-house Helium Leak Detection Testing is must to ensure maintenance of Stored Pressure in the cylinder over a period of 5 Years.
  • Tamper-proof safety seal.
  • Fire Rating for class A : 1A and Class B: 8B needs to be provided for the extinguisher.
  • The firm should submit the product performance test report from NABL accredited Government Lab.
  • The extinguisher must have Pressure Gauge,
  • Gross Weight must not exceed 3.6 Kg & Empty Weight shall upto 1.6 Kg.
  • Maximum Height of the Can must be 344MM & Diameter upto 108MM
  • Discharge time not less than 08 Secs.
  • The Extinguisher must have controllable discharge mechanism to provide flexibility of releasing extinguishing agent on targeted fire location.
  • Minimum effective range 2 Meters.
  • Applicable on Class A, B and electrically started Fire.
  • Can Construction: Deep drawn & Mig CO2 welded.
  • Valve Construction: Forging & Machining.
  • Internal Coating of Can: Epoxy Powder coating.
  • External Coating of Can: Epoxy Polyester Powder coating.
  • Sheet metal thickness: 1.60MM.
  • 05 Years Warranty.
Mono Ammonium Phosphate 90 (06 Kg.) - Required Nos - 04
  • The current and valid BIS certification IS 15683:2006 needs to be submitted along with offer.
  • Dry chemical powder used as extinguishing agent shall be Mono Ammonium Phosphate with more than 90% concentration conforming to IS 14609:1999.
  • MSDS of the powder needs to be submitted along with the offer.
  • The product shall be EN Approved and CE marked.
  • The manufacturer has to submit 5 years warranty on the extinguishers
  • Vessel used in the manufacturing should be constructed using Deep Drawn Technology to keep seamless area not less than 70% of the cylinder.
  • Each vessel needs to be checked for tensile strength upto 35 kgf/cm2 and Manufacturer has to submit Hydrostatic pressure testing certificate for the same.
  • The extinguishers should be pressurized using high grade Dry Nitrogen as per IS 1747 standard. OEM declaration shall be submitted along with the offer.
  • In-house Helium Leak Detection Testing is must to ensure maintenance of stored pressure in the cylinder over a period of 5 Years. Tamper-proof safety seal.
  • Fire rating for class A : 2A and Class B: 21B needs to be provided for the extinguisher.
  • The firm shall submit the product performance test report from NABL accredited Government Lab.
  • The extinguisher must have pressure gauge.
  • Gross weight must not exceed 9.4 Kg & Empty weight shall upto 3.4 Kg.
  • Maximum height of the can must be 480MM & Diameter upto 160MM
  • Discharge time not less than 13 Secs.
  • The extinguisher must have controllable discharge mechanism to provide flexibility of releasing extinguishing agent on targeted fire location.
  • Minimum effective range 4 Meters.
  • Applicable on Class A, B and electrically started Fire.
  • Can construction: Deep drawn & mig CO2 welded.
  • Valve construction: Forging & Machining.
  • Internal coating of can: Epoxy powder coating.
  • External coating of can: Epoxy polyester powder coating.
  • Sheet metal thickness: 1.60MM.
  • 05 Years Warranty.
Clean Agent HFC-236fa (FE 36) 02 - Required Nos - 10
  • The Extinguishing agent used in fire Extinguisher must have Zero Ozone Depletion Potential.
  • The bidder must submit Letter of Authorisation from OEM for using Clean Agent (HFC-236fa) in Portable Fire Extinguisher.
  • The Clean Agent (HFC-236fa) should be listed under EPA’s SNAP program, Underwriters Laboratories and NFPA 2001.
  • The current and valid BIS certification IS 15683:2006 needs to be submitted along with offer.
  • The Product should be EN Approved and CE marked. Valid certificate as on date needs to be submitted alongwith the bid.
  • The Manufacturer has to provide minimum 05 years warranty on the extinguishers.
  • The bidder must submit Material Safety Data Sheet for HFC-236fa Gas.
  • The Extinguisher must have controllable discharge mechanism to provide flexibility of releasing extinguishing agent on targeted fire location.
  • Each vessel needs to be checked for tensile strength upto 35 kgf/cm2 and Manufacturer has to submit Hydrostatic pressure testing certificate for the same.
  • The extinguishers should be pressurized using high grade Dry Nitrogen as per IS 1747 standard. OEM declaration should be submitted.
  • Tamper-proof safety seal.
  • Can Construction : Deep drawn & CO2 Mig welded
  • Valve Construction : Forging & Machining
  • Internal Coating of Can : Epoxy Powder coating,
  • External Coating of Can : Epoxy Polyester Powder coating
  • In-house Helium Leak Detection Testing is must to ensure maintenance of Stored Pressure in the cylinder over a period of 05 Years.
  • Boiling point of Extinguishing agent should be -1.4C (29.5 F) @ 760 mm Hg.
  • Vapor pressure should be 272.4 kPa @ 25 C (77 F)
  • Melting point must be -98 C (-144 F)
  • Freezing point must be -103 C (-153 F)
  • Form must be Liquefied gas
  • Specific gravity must be 1.370 gm/cc
  • The firm must submit the product performance test report from NABL accredited Government Lab towards desired fire ratings.
Co2 Squeeze Grip 4.5 Kg - Required Nos - 09
  • The current and valid BIS certification IS 15683:2006 needs to be submitted along with offer.
  • Co2 gas based Fire Extinguisher-4.5 Kg.
  • The Extinguisher must have wheel type controllable discharge mechanism to provide flexibility of releasing extinguishing agent on targeted fire location.
  • Trolley Mounted type for easy weight management.
  • The Product should be EN Approved and CE marked.
  • Tamper-proof safety seal.
  • Minimum effective range 2 Meters.
  • The carbon dioxide gas shall conform to IS 15222 with latest amendment.
  • Discharge valve shall be conform to all the requirement given in IS 3224:2002 or latest version thereof.
  • The Co2 Cylinder shall be conform to all the requirement given in IS 7285:2004.
  • Gross Weight must not exceed 19.1 Kg & Empty Weight shall upto 14.6 Kg.
  • Maximum Height of the Can must be 860MM & Diameter upto 140 MM.
  • Discharge Time less than 13 Seconds.
  • Applicable on Class B, C and electrically started Fire.
  • Fire Rating for class B: 13B needs to be provided for the extinguisher.
  • Can Construction : Hot Spinning/Forging.
  • Valve Construction : Forging & Machining,
  • Internal Coating of Can : Not Applicable.
  • External Coating of Can : Spray Printing.
  • Sheet metal thickness :4.5MM
  • The Co2 Cylinder shall be PESO Approved.
  • The firm should submit the product performance test report from NABL accredited Government Lab.
  • 01 Years Warranty.